Potential ignition sources are anything that can provide enough heat or energy to start a fire.

Every fire needs three things: a source of heat (ignition), fuel and oxygen. This is the fire triangle. Take away any one side and a fire cannot start or keep burning. Identifying and controlling potential ignition sources is therefore one of the first steps in any fire risk assessment.

Quick answer: A potential ignition source is anything that could provide enough heat to start a fire. Common workplace examples include faulty or overloaded electrical equipment, hot work such as welding, smoking materials, naked flames, heaters, cooking equipment, hot surfaces, friction, static electricity and arson.

Why ignition sources matter in law

In England and Wales, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to carry out a fire risk assessment and take general fire precautions. Scotland and Northern Ireland have their own equivalent fire safety legislation. Where flammable or explosive substances are present, the Dangerous Substances and Explosive Atmospheres Regulations 2002 (DSEAR) also require employers to assess the risks and avoid ignition sources.

The first step of a fire risk assessment is to identify the fire hazards, meaning the sources of ignition, fuel and oxygen. The next is to identify the people at risk.

Common potential ignition sources at work

Ignition sourceTypical examples
ElectricalFaulty wiring, damaged leads, overloaded sockets and extension leads, equipment left charging, poorly maintained appliances
Hot workWelding, cutting, grinding and brazing, which produce sparks and hot metal
SmokingDiscarded cigarettes and matches, especially near bins or stored waste
Naked flamesCandles, blowtorches, gas burners and pilot lights
HeatingPortable heaters placed near combustibles, blocked heater vents
CookingUnattended cooking, grease build-up in extraction ducts, toasters and microwaves in offices
Hot surfaces and lightingHalogen lamps, hot engines, flues and process equipment
Friction and mechanicalOverheating bearings, worn belts and moving parts
Static electricityPouring or transferring flammable liquids and powders
ArsonDeliberate fire-setting, often using unsecured waste or combustibles left outside

How to control ignition sources

The aim is to remove ignition sources where you can, and keep the rest well away from fuel.

  • Electrical safety: inspect and maintain fixed wiring and portable equipment, avoid daisy-chaining extension leads and switch off equipment that does not need to be left on.
  • Hot work permits: use a permit-to-work system for welding and cutting, clear or protect combustibles, provide extinguishers and keep a fire watch during and after the work.
  • Smoking policy: ban smoking indoors, provide a safe designated area away from the building and stored materials, with suitable bins.
  • Heaters and cooking: keep heaters clear of combustibles, never leave cooking unattended and clean extraction systems regularly.
  • Maintenance: lubricate and maintain machinery to prevent friction and overheating.
  • Flammable substances: under DSEAR, control releases, use suitable equipment in hazardous areas and manage static, for example by earthing and bonding.
  • Arson prevention: secure the site, store waste away from buildings and keep bins locked.

Don’t forget the fuel side

Controlling ignition sources is only half the picture. Good housekeeping keeps fuel away from heat: remove waste regularly, store flammable liquids in suitable containers and cabinets, and keep escape routes clear of combustible materials.

Training

If you are responsible for fire safety, our fire marshal training covers ignition sources, fire prevention and what to do in an emergency. For people who carry out fire risk assessments, the NEBOSH Fire Certificate is the recognised qualification.

FAQs

Frequently asked questions

What is an example of a potential ignition source?

Common examples include faulty electrical equipment, hot work such as welding, cigarettes, naked flames, portable heaters, cooking equipment, hot surfaces, friction and static electricity.

What are the three elements of the fire triangle?

Heat (an ignition source), fuel and oxygen. Remove any one of them and a fire cannot start or continue.

Who is responsible for controlling ignition sources?

The responsible person under fire safety law, usually the employer or the person in control of the premises, must assess the risk and put precautions in place.

What is a hot work permit?

A permit-to-work for activities such as welding and cutting. It sets out the precautions needed before, during and after the work, including fire watch and extinguishers.


Responsible for fire safety? Call 01264 317032 to talk through fire marshal and NEBOSH Fire Certificate training.

Controlling potential ignition sources

HSE explains how to manage potential ignition sources in its fire and explosion guidance. Spotting potential ignition sources is a core part of every fire risk assessment.

LinkedIn
Facebook
Email
ABOUT SWT
SWT Health and Safety Training

A veteran-owned training provider and NEBOSH Gold Learning Partner, accredited by NEBOSH, IOSH and ProQual and an approved ELCAS provider (No. 8747). Courses are delivered by our experienced training team in Amesbury, online and on site across the UK.

More about us  ·  Get in touch
On this page
TALK TO US
Not sure which course is right for you?

Our veteran-led team will help you choose, check ELCAS or payment plan options and find a date.

Call 01264 317032Send us a message

More articles you may find useful

The Control of Substances Hazardous to Health Regulations explained: which substances are covered, the 8 steps to compliance and how to carry out a COSHH assessment.
Plan, Do, Check, Act is the backbone of good health and safety management. Here is how it works, how HSG65 and ISO 45001 use it, and practical examples for your workplace.
The Work at Height Regulations 2005 explained: what counts as working at height, the hierarchy of control, planning and competence, and when ladders are acceptable.